Lamella Eliminator Type TAV

The drops, created by distribution of liquids don´t have to be carries out together with the gas flow. Demister and aerosol collection systems have a wide range of applications, i.e. in order to keep material consumption as low as possible, to protect following processes against harmful media or for pollution control reasons.

Application:

For horizontal installation and at high separation.

Versions:

The lamella separators are made of packages with S-shaped profiles. Its surface is specially structured and provided with cardboard strips. Number and pitch of the individual profiles in a profile package can be varied depending on the requirement profile. Combined with our demister DA higher separation can be achieved.

Function:

The flowing gas is forced through the profiles to a flow diversion. This can´t follow the drops due its inertia. They bounce off the surface profile and form a flowing down liquid film.

pv_169_lamella_separators

Description

Pressure

Pressure loss With a flow rate of 9 m/s in the pipe max. 200 Pa (applies to water / air at 20°C without wire mesh )

Temperature

Standard
PP 0°C until 100°C
PE - 20°C until 60°C
PVC 0°C until 60°C
PVDF - 20°C until 120°C

 

Special design as welded construction
PVC -C - 20°C until 80°C
ECTFE - 20°C until 150°C