Lamella Eliminator Type TAV
The drops, created by distribution of liquids don´t have to be carries out together with the gas flow. Demister and aerosol collection systems have a wide range of applications, i.e. in order to keep material consumption as low as possible, to protect following processes against harmful media or for pollution control reasons.
Application:
For horizontal installation and at high separation.
Versions:
The lamella separators are made of packages with S-shaped profiles. Its surface is specially structured and provided with cardboard strips. Number and pitch of the individual profiles in a profile package can be varied depending on the requirement profile. Combined with our demister DA higher separation can be achieved.
Function:
The flowing gas is forced through the profiles to a flow diversion. This can´t follow the drops due its inertia. They bounce off the surface profile and form a flowing down liquid film.
Data sheet
Description
Pressure
Pressure loss With a flow rate of 9 m/s in the pipe max. 200 Pa (applies to water / air at 20°C without wire mesh )
Temperature
Standard
PP | 0°C | until | 100°C |
PE | - 20°C | until | 60°C |
PVC | 0°C | until | 60°C |
PVDF | - 20°C | until | 120°C |
Special design as welded construction
PVC -C | - 20°C | until | 80°C |
ECTFE | - 20°C | until | 150°C |